Johnathan Corgan 8265f1f41e Pin the flap-dampening re-arm and the coordinate-gate ordering
Both fixes shipped green with no test that would fail if they were reverted.

The dampening tests drive a second episode after the first lapses, which
none of the six existing tests attempted; the one that looked closest
engages with a zero-second duration and never re-arms. Break-checked by
reverting the lapse-aware gate.

The gate-ordering tests pin that an inadmissible coordinate signal never
reaches the response rate limiter at all. Moving the gate below the
limiter left both existing tests green, because a false return from the
limiter does not short-circuit the handler, so the attacker-chosen
address still lands in a map pruned only every ten seconds.

Green: fmt, build, clippy and test --lib, 1526 passed.
2026-08-15 07:21:44 +00:00
..